Output signal
|
VOLTAGE
|
CURRENT
|
|
Non Linearity (BFSL)
|
± 0.15% FS (typ) ± 0.25% FS (max)
|
|
Hysteresis
|
+ 0.1% FS (typ) + 0.15% FS (max)
|
|
Repeatability
|
± 0.025% FS (typ) ± 0.05% FS (max)
|
|
Zero offset tolerance
|
± 0.15% FS (typ) ± 0.25% FS (max)
|
|
Span offset tolarance
|
± 0.15% FS (typ) ± 0.25% FS (max)
|
|
Accuracy at room temperature (1)
|
< ± 0.5% FS
|
|
Pressure ranges (2)
|
From 0 bar to 600 bar
|
|
Resolution
|
Infinite
|
|
Overpressure (without degrading performance)
|
See table
|
|
Pressure containment (burst test)
|
See table
|
|
Pressure Media
|
Fluids compatible with Stainless Steel AISI 430F and 17-4 PH
|
|
Housing
|
Stainless Steel AISI 304
|
|
Power supply
|
15…30Vdc
|
10…30Vdc
|
|
Non Linearity (BFSL)
|
250 Vdc
|
|
Zero output signal
|
0 V (N); 0.1 V (C)
|
4 mA (E)
|
|
Full scale output signal
|
10 V (N); 10.1 V (C)
|
20 mA (E)
|
|
Allowed load
|
≥ 5KΩ
|
see load diagram
|
|
Long term stability
|
< 0.2% FS/per year
|
|
Operating temperature range (process)
|
-40…+125°C (-40…+257°F)
|
|
Operating temperature range (ambient)
|
-40…+105°C (-40…+221°F)
|
|
Compensated temperature range
|
-20…+85°C (-4…+185°F)
|
|
Storage temperature range
|
-40…+125°C (-40…+257°F)
|
|
Temperature effects over compensated range (zero)
|
± 0.01% FS/°C typ. (± 0.02% FS/°C max.)
|
|
Temperature effects over compensated range (span)
|
± 0.01% FS/°C typ. (± 0.02% FS/°C max.)
|
|
Response time (10…90%FSO)
|
< 1 msec
|
|
Warm-up time (3)
|
< 30 sec.
|
|
Mounting position effects
|
Negligible
|
|
Humidity
|
Fino a 100%RH non-condensing
|
|
Weight
|
80-120 gr. nominal
|
|
Mechanical shock
|
100g/11msec according to IEC 60068-2-27
|
|
Vibrations
|
20g max at 10…2000 Hz according to IEC 60068-2-6
|
|
Ingress protection
|
IP65/IP67
|
|
Output short circuit and reverse polarity protection
|
YES
|
|
CE Conformity
|
According to EC Directive 2004/108/CE
|